HITEMA ICE-RINK CHILLERS
HITEMA INDUSTRIAL CHILLERS AIR-COOLED ICE-RINK CHILLERS Cooling Capacity from 5kW to 100kW STANDARD FEATURES: ◾️ Digital Parametric Microprocessor; ◾️ Protection Rating IP54/NEMA 3R; ◾️ High Efficiency Plate Evaporator in stainless steel; ◾️ BMS connectivity; ◾️ Integrated Hydraulic Circuit; ◾️ High/Low pressure Gauges; ◾️ LWT: -30°C/-22°F; ◾️ Ecodesign compliant with REGULATION 2015/1095. ...
-
Premium
HITEMA DATA CENTER CHILLERS
HITEMA INDUSTRIAL CHILLERS DATA-CENTER CHILLERS LOW GWP OFFER + HYBRID EVAPORATOR MAIN FEATURES: ▪ Intelligent Controls Optimize Energy ▪ Air to Liquid Free Cooling Coils ▪ Optimized Hybrid Cooling System ▪ Very Fast Payback ▪ Quick Start Function ▪ Eco – Friendly Refrigerants R 1234ze (GWP=3) ▪ Safety Class A2L ▪ E-coating condenser ▪ Ecodesign compliant with REGULATION 2015/1095. Contact us ...
-
Premium
Cosmos - Model XPS-7 - Semiconductor Plant Gas Detector - Instruction Manual
Thank you for purchasing the XPS-7 Semiconductor Plant Gas Detector. To ensure correct operation, please read this operation manual carefully. This product is designed to detect gas leaks in semiconductor manufacturing plants. Sensor units (purchased separately) can be switched to detect a variety of gases. Read and be sure you fully understand this manual even if you have used a Gas Detector ...
-
Premium
Hitema - Model TFVF Series - Free-Cooling Liquid Chillers with EC Axial Fans - Technical Datasheet
TFVF SERIES are Air-Cooled liquid chillers with integrated Free-Cooling. These chillers are designed for applications that require reliability, continuity of operation, the best performance and very low management costs. All the models are equipped with flooded evaporator or Hybrid film evaporator. Flooded evaporator ensures the best performances for the low approach point in the evaporating ...
-
Premium
Hitema - Model Ice-Rink Series - Process Chillers - Brochure
ICE-RINK SERIES consists of Standard and Customized Air-Cooled Chillers designed for applications that require reliability, continuity of operation, high performance, reduced management costs and Ice-Rink ...
-
Premium
Hitema - Model ENRC Series - Condenserless Liquid Chillers - Technical Datasheet
STANDARD CONFIGURATION: Compressors: Scroll. Condenser and fans: At costumer care. Evaporator: Coaxial (models 008÷100) or Shell & Tube (models 130÷430). Expansion Valve: Thermostatic. Protection Rating: IP54. Refrigerant: R410A, R454B; ...
-
Premium
Hitema - Model CWB Series - Condenserless Liquid Chillers - Technical Datasheet
STANDARD CONFIGURATION: Compressors: Screw. Condenser and fans: At costumer care. Evaporator: Shell & Tube. Expansion Valve: Electronic. Protection Rating: IP54. Refrigerant: R134a; R513A and R1234ze. Cooling Capacity Renge 291kW ÷ 2240kW. Available with 1 , 2 or 3 Refrigerant ...
-
Premium
Hitema - Model CFTC Series - Condenserless Liquid Chillers - Technical Datasheet
STANDARD CONFIGURATION: Compressors: Scroll (models 061÷430). Condenser: At costumer care. Evaporator: 1x Brazed plate (CFTC.061÷185) 2x Brazed plate (CFTC.200÷430). Expansion Valve: Thermostatic. Fans: At costumer care. Protection Rating: IP54. Refrigerant: R410A, R454B; R32 (chiller provided with Nitrogen charge at 5 bars). Cooling Capacity Renge 50kW ÷ ...
-
Premium
Hitema - Model TFV Series - Air-Cooled Liquid Chillers With EC Axial Fans - Technical Datasheet
Standard Configuration:. Compressors: Turbocor. Condenser: Air-Cooled, with copper tubes and aluminium finned core. Evaporator: Flooded. Expansion Valve: Electronic. Fans: EC axial. Protection Rating: IP54. Refrigerant: R134a; R1234ze. Cooling Capacities Renge 250kW ÷ ...
-
Premium
Hitema - Model PRP Series - Modular Air-Cooled Liquid Chillers with Axial Fans - Technical Datasheet
PRP SERIES are aircooled liquid modular chillers with natural refrigerant R290. R290 represents one of the most attractive alternative to the traditional HFC refrigerants characterized by high GWP. This natural fluid has a zero ozone depletion potential (ODP = 0), a negligible direct greenhouse affect (GWP = 3) and also has very high coefficient of performance. As a result, the life cycle costs ...
-
Premium
Hitema - Model SBS-MC Series - Modular Chiller with Microchannel Condenser - Datasheet
Modular air-cooled liquid chillers SBS-MC series, scroll compressors, 2 refrigrant circuits with one brazed plate evaporator per circuit and aluminum microchannel condenser coils to minimize the refrigerant charge (R410A / R32 / R454B). AC axial fans controlled by cut-phase speed regulator. Electrical feed 400V/3ph/50Hz, IP54 protection rating, chillers suitable for outdoor installation. You can ...
-
Premium
Hitema - Model SBSF-OPT Series - Optimized Free-Cooling Liquid Chillers with Axial Fans - Technical Datasheet
Free-cooling liquid chillers SBSF series, scroll compressors, R410A / R32 / R454B refrigerant, brazed plate / shell and tube evaporator, 1÷3 refrigerating circuits, condenser coil with copper tubes and aluminium fins, integrated and optimized free-cooling coils, AC axial fans. IP54 protection rating, chillers suitable for outdoor installation. Additional modules (2 fans) can be added to ...
-
Premium
XP-703D Gas Leak Detector for Semiconductor Manufacturing Gases - Brochure
Features:Best suited for detecting trace leaks of semiconductor manufacturing gases. Detects gas leaks and alerts you by lamp and ...
-
Premium
HANDHELD pH INSTRUMENTS - Technical Reference
Definition: pH is the negative logarithm of hydrogen ion activity in a solution. The Concentration ratio of hydrogen ions (H+) and hydroxyl ions (OH-) determine the pH value of a solution. Any hydrogen activity will produce a 59.16 mV/ pH unit across the glass membrane. The measurement is expressed on a scale of 0.0 to 14.0. Water with a pH of 7 is considered neutral (H+ ions = 10-7 and OH-ions ...
-
Premium
Laboratory application brochure- LNI
Nowadays on-site gas generation has shown many advantages over pressure gas cylinders in laboratories: it is cost-effective offering continuous hydrogen, nitrogen and zero air and avoiding cumbersome cylinders, rental or high logistic costs. But it is also safer (lower volume and pressure) and green allowing a reduction in the carbon footprint and the use of renewable resources such air, water ...
By LNI Swissgas
-
Premium
Hitema - Model ENRF Series - Aircooled Liquid Chillers - Technical Datasheet
Free-cooling liquid chillers ENRF series, scroll compressors, R410A / R32 / R454B refrigerant, coaxial / shell and tube evaporator, condenser and free-cooling coil with copper tubes and aluminium finned fins, AC axial fans regulated with cut phase fan speed regulator. Electrical feed 400V/3ph/50Hz. IP54 protection rating, chillers suitable for outdoor installation. Inbuilt water storage tank and ...
-
Premium
Hitema - Model SBS Series - Air-Cooled Liquid Chillers with Axial Fans - Technical Datasheet
Air-cooled liquid chillers SBS series, scroll compressors, R410A / R32 / R454B refrigerant, brazed plate / shell and tube evaporator, 1÷4 refrigerating circuits, condenser coil with copper tubes and aluminium fins, AC axial fans. IP54 protection rating, chillers suitable for outdoor installation. Additional modules (2 fans) can be added to improve efficiency (before the order). Inbuilt ...
-
Premium
Hitema - Model NOVA Series - Air-Cooled Liquid Chillers with Axial Fans - Brochure
Standard Configuration:. Compressors:Screw. Condenser:Air-Cooled, with copper tubes and aluminium finned core. Evaporator:Shell & Tube. Expansion Valve: Electronic. Fans: AC axial. Protection Rating: IP54. Refrigerant: R134a; R513A and R1234ze. Cooling Capacity Renge: 283kW ÷ ...
-
Premium
Hitema - Model ENR Series - Aircooled Liquid Chillers - Technical Datasheet
Air-cooled liquid chillers ENR series, rotary / scroll compressors, R410A / R32 / R454B refrigerant, brazed plate / coaxial / shell and tube evaporator, condenser coil with copper tubes and aluminium finned fins, AC axial fans. IP54 protection rating, chillers suitable for outdoor installation. Inbuilt water storage tank and single pump P3 as ...
-
Premium
Hitema - Model CSE Series - Aircooled Liquid Chillers - Technical Datasheet
Air-cooled liquid chillers CSE series, scroll compressors, R410A / R32 / R454B refrigerant, coaxial / shell and tube evaporator, condenser coil with copper tubes and aluminium finned fins, centrifugal fans with available air static pressure of 200Pa. Electrical feed 400V/3ph/50Hz. IP44 protection rating, chillers suitable for INDOOR installation. Inbuilt water storage tank and single pump P3 as ...